Abstract:According to the requirement of the performance test of the anti-suffocation valve on mask and the research of its effect on the breathing mode of human body, a multi parameter collection, analysis and statistics integrated test system was developed. The system is based on CompactDAQ platform, collecting of mask pressure and ventilation flow signals, and developed by LabVIEW software. The parameters such as opening pressure, suction resistance, ventilation flow peak value, tidal volume and respiratory frequency can be analyzed and counted. According to the experiment, the system has the ability to test the main performance of the anti-suffocation valve and analyze the respiratory parameters of human body. The system is portable, extensible, friendly human-machine interface and reliable operation possessed. It can meet the needs of test and research of anti-suffocation valve. At the same time, the design method of the system provides a way for the test of other performance parameters on oxygen mask.