Abstract:In the view of the actual measurement sensor is nonlinear, The method of using modified Wiener model to describe the dynamic nonlinear sensor model is proposed in this paper. Respectively using Laguerre function and least squares support vector machine for the identification of dynamic linear part and nonlinear static link of the Wiener model. Through simulation experiment to compare the speed and identification error of different methods,the results show that this method in the identification of nonlinear dynamic sensors has an obvious advantage.